Skip to content
ISO 45001 AlignedISO 13031 Compliant

Safety Starts
In the Design

Our health and safety management system is aligned with ISO 45001. Every attachment is engineered with operator safety as a core requirement.

Our Commitment to Safety

At Sieruta, safety is not an afterthought — it's engineered into every attachment from the first CAD drawing to final delivery. We protect three groups:

Manufacturing Team

Fabrication, welding, and finishing operations

Field Operators

Operators using our attachments daily

Site Personnel

People working near excavators on job sites

Certification In Progress

Workplace Safety Management (ISO 45001)

Risk Assessment & Control

  • Hazard identification for all manufacturing operations
  • Risk ranking and control measure implementation
  • Regular safety audits and inspections
  • Near-miss reporting and investigation

Training & Competency

  • Welding certification (AWS D1.1 qualified welders)
  • Equipment operation training and authorization
  • PPE training and enforcement
  • Emergency response procedures

Safety Culture

  • Worker involvement in safety decisions
  • Stop-work authority for unsafe conditions
  • Continuous improvement through incident analysis
  • Contractor safety management

Evidence Available: Health & Safety Policy PDF, Training Overview, Visitor Safety Rules. Contact safety@sieruta.com for procurement packets.

Critical Safety Standard

Quick Coupler Safety (ISO 13031)

OSHA has documented 15 quick coupler-related fatalities over 7 years. Proper safety mechanisms prevent unexpected attachment release that can cause severe injury or death. All Sieruta hydraulic quick couplers meet ISO 13031 safety requirements.

Front Lock

Primary locking at front prevents fall-forward release

ISO 13031 Mandatory

Safety Springs

Maintains lock even with hydraulic failure

ISO 13031 Mandatory

Visual Indicator

LED or paint marking shows lock engagement

ISO 13031 Recommended

Connection Test

Operator can verify secure attachment before lift

Best Practice
Operator Required

Before Each Use: Operator Checklist

Quick Coupler Inspection

  • Visual inspection of locking mechanism (no damage, wear, or deformation)
  • Verify safety pin engagement (fully seated, not bent)
  • Check hydraulic lines for leaks, damage, or loose fittings
  • Test lock/unlock cycle (no sticking or unusual resistance)
  • Confirm visual/audible lock indicator (if equipped)

Attachment Inspection

  • Check for cracks in welds or structural damage
  • Verify all pins and hardware are secure
  • Inspect wear components (edges, teeth) for excessive wear
  • Check bucket interior for debris or foreign objects
  • Verify quick coupler mounting is tight (no play or movement)

Ground-Level Connection Test

  • Attach quick coupler with attachment on ground
  • Verify lock engagement (visual + audible confirmation)
  • Attempt to lift attachment slightly and lower
  • Re-verify lock before full lift operation

Safe Operation Guidelines

Quick Coupler Connection

  • • Always connect/disconnect on level ground
  • • Never attach/detach while bucket is suspended
  • • Verify lock engagement before lifting
  • • Re-check locks after first movement
  • • Never rely on hydraulic pressure alone to hold attachment

Load Management

  • • Know your machine's rated capacity
  • • Account for attachment weight + material load
  • • Avoid side-loading or twisting under load
  • • Do not exceed manufacturer's pin size specifications
  • • Use proper lifting technique (gradual, controlled)

Work Zone Safety

  • • Maintain exclusion zone around excavator
  • • Use spotter for blind spots or restricted visibility
  • • Never swing loads over personnel
  • • Ensure stable ground before operations
  • • Follow site-specific safety protocols

Recommended Inspection Intervals

Daily
Before Each Use
  • Visual inspection of quick coupler and attachment
  • Locking mechanism function test
  • Hydraulic line check
  • Wear component assessment
Weekly
7 Days
  • Detailed coupler pin wear measurement
  • Hardware torque verification
  • Lubrication of pivot points
  • Weld inspection (visual check for cracks)
Monthly
30 Days
  • Dimensional verification (pin holes, mounting points)
  • Structural integrity assessment
  • Hydraulic system pressure test (if applicable)
  • Documentation review (maintenance records)
Annually
12 Months
  • Professional inspection and certification
  • Non-destructive testing (ultrasonic weld inspection)
  • Pin replacement (if wear limits exceeded)
  • Update maintenance records

Safety Training Materials

  • Quick Coupler Safety Video (15 min)
  • Pre-Use Inspection Checklist (printable PDF)
  • Maintenance Schedule Template
  • Incident Reporting Form
  • ISO 13031 Compliance Statement

Custom Training

We provide on-site or remote safety training for fleet managers, new operators, and safety officers conducting equipment audits.

Contact: training@sieruta.com

Report Safety Concerns

If you experience a safety incident involving a Sieruta attachment, follow these steps immediately:

  1. 1Ensure immediate safety (secure equipment, tend to injuries)
  2. 2Document the incident (photos, description, serial number)
  3. 3Contact us immediately
  4. 4Preserve attachment for inspection (do not modify or repair)
  5. 5Cooperate with investigation

Emergency Contact

We treat all safety reports with urgency and confidentiality.